CalculatorCardiology
Aortic regurgitation: regurgitant orifice by PISA
Aortic effective regurgitant orifice area and regurgitant volume from the proximal isovelocity surface area.
Updated 31 October 2026
When to use it
Echocardiography of aortic regurgitation with a visible flow convergence on the ventricular side of the valve.
What it needs
- PISA radius
- Aliasing (Nyquist) velocity
- AR jet peak velocity (continuous-wave Doppler)
- AR jet velocity–time integral
Formula
Flow = 2π × r² × Va
EROA = Flow / AR Vmax
Regurgitant volume = EROA × AR VTI
How to interpret it
| Result | Interpretation |
|---|---|
| < 0.1 | Mild AR (< 0.10 cm²) |
| 0.1 to < 0.3 | Moderate AR (0.10–0.29 cm²) |
| ≥ 0.3 | Severe AR (≥ 0.30 cm²) |
In the app it also calculates: Regurgitant volume.
Practical tip
In AR the PISA is harder to obtain than in MR (apical 5-chamber or high parasternal window) and is less reliable with eccentric jets or a dilated aorta.
2 more practical tips in the app.
Reference
A support tool for healthcare professionals: it guides and does not replace clinical judgement.