CalculatorCardiology
Aortic valve area by the Gorlin formula
Estimates the area of a stenotic aortic valve from cardiac catheterisation haemodynamics.
Updated 30 October 2026
When to use it
Cardiac catheterisation with measured cardiac output and mean transaortic gradient, especially when echocardiography is inconclusive.
What it needs
- Cardiac output
- Heart rate
- Systolic ejection period
- Mean transaortic gradient
Formula
AVA (cm²) = CO (mL/min) / (HR × SEP × 44.3 × √mean gradient)
SEP = systolic ejection period (s/beat)
How to interpret it
| Result | Interpretation |
|---|---|
| < 1 | Severe aortic stenosis (< 1.0 cm²) |
| 1 to < 1.5 | Moderate aortic stenosis (1.0–1.5 cm²) |
| ≥ 1.5 | Mild aortic stenosis (> 1.5 cm²) |
Practical tip
At low cardiac output the formula tends to underestimate the area (the discharge coefficient is not constant): consider a dobutamine study.
2 more practical tips in the app.
Reference
- Gorlin R, Gorlin SG. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. Am Heart J. 1951;41(1):1-29.
- Baumgartner H, Hung J, Bermejo J, et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European Association of Cardiovascular Imaging and the American Society of Echocardiography. J Am Soc Echocardiogr. 2017;30(4):372-392.
A support tool for healthcare professionals: it guides and does not replace clinical judgement.