CalculatorCardiology
Mitral valve area by the Gorlin formula
Calculates the area of a stenotic mitral valve from diastolic flow and mean gradient measured at catheterisation.
Updated 30 October 2026
When to use it
Mitral stenosis assessed by catheterisation, especially when echocardiography is discordant or inconclusive.
What it needs
- Cardiac output
- Heart rate
- Diastolic filling period
- Mean transmitral gradient
Formula
Diastolic flow (mL/s) = CO (mL/min) / (HR × DFP)
MVA (cm²) = diastolic flow / (37.7 × √mean gradient)
DFP = diastolic filling period (s/beat); 37.7 = 44.3 × 0.85
How to interpret it
| Result | Interpretation |
|---|---|
| < 1.005 | Very severe mitral stenosis (≤ 1.0 cm²) |
| 1.005 to < 1.505 | Severe mitral stenosis (1.0–1.5 cm²) |
| ≥ 1.505 | Non-severe mitral stenosis (> 1.5 cm²) |
In the app it also calculates: Transmitral diastolic flow.
Practical tip
Using pulmonary wedge pressure instead of direct left atrial pressure overestimates the gradient and underestimates the area, particularly with mitral prostheses.
2 more practical tips in the app.
Reference
- Gorlin R, Gorlin SG. Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I. Am Heart J. 1951;41(1):1-29.
- Otto CM, Nishimura RA, Bonow RO, et al. 2020 ACC/AHA Guideline for the Management of Patients With Valvular Heart Disease. Circulation. 2021;143(5):e72-e227.
A support tool for healthcare professionals: it guides and does not replace clinical judgement.