CalculatorCardiology

Cardiac output by the Fick method

Cardiac output and cardiac index from oxygen consumption and the arteriovenous O₂ difference.

Updated 31 October 2026

When to use it

Right heart catheterisation or critically ill patients with known mixed venous (pulmonary artery) and arterial saturations.

What it needs

  • WeightUnits: kg, lb
  • HeightUnits: cm, in
  • HaemoglobinUnits: g/dl, g/l
  • Arterial O₂ saturation (SaO₂)Units: %
  • Mixed venous O₂ saturation (SvO₂)Units: %
  • Oxygen consumptionOptions: Estimated (125 mL/min/m²) · Measured
  • Measured VO₂ (optional)Units: ml/min

Formula

BSA (Mosteller) = √(height cm × weight kg / 3600)

VO₂ = measured, or estimated 125 mL/min/m² × BSA

CaO₂ − CvO₂ (mL/dL) = 1.34 × Hb × (SaO₂ − SvO₂)/100

CO (L/min) = VO₂ / (10 × (CaO₂ − CvO₂))

CI = CO / BSA

How to interpret it

The result is read in its clinical context; the app shows it with its units and warnings.

In the app it also calculates: Arteriovenous O₂ difference, Cardiac output, Cardiac index.

Practical tip

Estimated VO₂ (125 mL/min/m²) is the largest source of error: in the elderly, septic, febrile or sedated patients true consumption may differ by more than 25 %. Measure it when possible.

2 more practical tips in the app.

Reference

A support tool for healthcare professionals: it guides and does not replace clinical judgement.

Back to top