CalculatorCardiology

Dimensionless velocity index in aortic stenosis (DVI)

Ratio of outflow tract to aortic valve flow, independent of the LVOT diameter.

Updated 30 October 2026

When to use it

Echocardiography of aortic stenosis when the LVOT diameter is uncertain, or to follow the same patient over time.

What it needs

  • LVOT velocity–time integral (pulsed-wave Doppler)Units: cm
  • Aortic valve velocity–time integral (continuous-wave Doppler)Units: cm
  • LVOT diameter (optional, to estimate the area) (optional)Units: cm, mm

Formula

DVI = LVOT VTI / aortic VTI (or LVOT peak velocity / aortic peak velocity)

Optional AVA = π × (LVOT diameter / 2)² × DVI

How to interpret it

Dimensionless velocity index (DVI)
ResultInterpretation
< 0.25Consistent with severe aortic stenosis (< 0.25)
0.25 to < 0.5Moderate aortic stenosis (0.25–0.50)
≥ 0.5Mild or no stenosis (> 0.50)

In the app it also calculates: Estimated aortic valve area.

Practical tip

It avoids the most common error of the continuity equation: squaring a poorly measured LVOT diameter.

2 more practical tips in the app.

Reference

A support tool for healthcare professionals: it guides and does not replace clinical judgement.