CalculatorCardiology

Simplified ejection fraction (LV diameters)

Estimates LV ejection fraction from the shortening of the squared end-diastolic and end-systolic diameters.

Updated 31 October 2026

When to use it

Quick M-mode or 2D estimate when biplane Simpson is not feasible and the LV has no regional wall motion abnormalities.

What it needs

  • LV end-diastolic diameterUnits: cm, mm
  • LV end-systolic diameterUnits: cm, mm

Formula

EF (%) = (LVIDd² − LVIDs²) / LVIDd² × 100

How to interpret it

Estimated ejection fraction (%)
ResultInterpretation
≤ 29Severely reduced (< 30 %)
30–40Moderately reduced (30–40 %)
41–51Mildly reduced (41–51 %; up to 53 % in women)
≥ 52Normal (≥ 52 % men, ≥ 54 % women)

Practical tip

It assumes uniform contraction: with regional abnormalities (especially apical) it greatly over- or underestimates EF. Current guidelines recommend biplane Simpson or 3D.

2 more practical tips in the app.

Reference

A support tool for healthcare professionals: it guides and does not replace clinical judgement.